INST develops new kit to detect fluoride in drinking water

▴ INST develops new kit to detect fluoride in drinking water
Equipment-free, a simple paper-strip based naked-eye fluoride ion detection and quantification kit in drinking water to evade Fluorosis-based disorders

Fluorosis is a crippling disease resulting from the deposition of fluorides in the hard and soft tissues of the body due to excess intake of fluoride through drinking water/food products/industrial pollutants over a long period. It results in dental fluorosis, skeletal fluorosis, and non-skeletal fluorosis. Easy detection of fluorides in water can help preventing the public health hazards.

Scientists from the Institute of Nano Science and Technology (INST), an autonomous institute of the Department of Science and Technology, Government of India, have developed an equipment-free fluoride ion detection and quantification in drinking water with the naked-eye. It can be operated by non-experts for household use to evade Fluorosis-based disorders.

The technology developed by Dr. Jayamurugan Govindasamy and his team involves a push-pull chromophore based on 2,3-disubstituted 1,1,4,4-tetracyano-1,3-butadienes (TCBDs) that changes color upon exposure to fluoride ion. The identified chromophore (C3-phenyl, C2-urea functionalized TCBD) is the result of a systematic study seeded by the Early Career Research (ECR) Award and further supported by the Ramanujan Fellowship grant of DST received by Dr. Govindasamy. The results were recently published in the Journal of Organic Chemistry. The researchers designed urea as an unusual donating moiety instead of traditional donor moieties, such as amines, to obtain better optoelectronic properties. The charge-transfer (CT) property that arises through-bond in aniline donor is usually quenched due to a photoinduced electron transfer (PET) mechanism. Whereas upon introducing urea as an electron donor, the CT exhibited both spaces as well as through bond due to “Field-effect”. Thus partial overcoming of the PET process, which led to white light emission.

Later, they extended its applicability in sensing of biologically relevant fluoride, as it is well known that fluoride can bind with urea via H-bonding interaction. Thus the combination of the push-pull chromophore with urea turned out to be an ideal system for the same. The INST scientists have optimized the synthesis of this chromophore in the laboratory scale

Furthermore, the design and synthesis can be slightly modulated to increase the sensitivity from 3 ppm to less than 1 ppm. Currently, the INST team is working in this direction. The major cost involves only the synthesis of the chromophore, making it affordable and accessible.

Although a vast number of reports are available for chromogenic and chromo-fluorogenic receptors in solution, only a limited number of reports which studied solid-phase detection. However, all those receptors suffer some drawbacks such as they generally exhibit color change only in organic medium and inorganic fluoride source, competing for affinity towards other anions such as acetate and phosphate, with a relatively high minimum detection limit of 10–30 ppm, work only with concentrated HCl, use of metals, delayed response, etc. while some works only with UV-lamp and chemically treated paper.

The non-planar push-pull chromophores sense fluoride ion with the naked eye in both solutions- as well as solid-phases.

The invention has been protected by filing the patent (202011028595). This work was supported by DST-SERB through the Early Career Research Award and Ramanujan Fellowship to Dr. JayamuruganGovindasamy.

Several companies sell solution-based photometric as well as colorimetric sensor kit, including few Indian companies. However, there is no single product based on low-cost paper-strip available to bring down the cost of the kit as well as easy handling by a layman.

Currently, one German company sells a paper-strip test kit for the detection of HF with a sensitivity of up to 20 ppm that too works only with hydrochloric acid (pH<1). This kit developed by INST can be used by a non-expert, with high sensitivity up to 3 ppm in aqueous/DMSO 1:1 condition and with only DMSO up to 1 ppm and free of dangerous chemicals and equipment.

Tags : #Fluorosis #DrinkingWater #DrJayamuruganGovindasamy #DST #INST #JournalofOrganicChemistry #GovtofIndia

About the Author


Team Medicircle

Related Stories

Loading Please wait...

-Advertisements-




Trending Now

Bharti Singh's Battle with Gallstones: Symptoms, Precautions, and Natural RemediesMay 04, 2024
Empowering Women's Health: New Mammogram GuidelinesMay 04, 2024
Rising Temperatures, Rising Risks: Addressing the Challenges of Heat StressMay 04, 2024
Gynoveda, India's First Ayurveda Fertility Company, Expands Reach with New Clinic in Pune, Set to Open 100 Clinics Across India by 2027May 03, 2024
Aptus Value Housing Finance India Limited, a leading Housing Finance Company has declared its financial results for the year ended March 31, 2024. FY 24 ResultsMay 03, 2024
TIPS FOR PREGNANCY CARE DURING SUMMERMay 03, 2024
The deadly intersection: TB and tobacco smoking co-epidemics in Indonesia Dr TARA SINGH BAM – CNSMay 03, 2024
Mintoak Expands Global Footprint with Strategic Leadership AppointmentsMay 03, 2024
The Future of Healthcare: 10 ways Telehealth is Improving Patient Outcomes and Reducing CostsMay 03, 2024
Understanding the Effects of a Keto Diet on Your Body: A One-Month JourneyMay 03, 2024
High Blood Pressure in Youth: A Precursor to Severe Heart ConditionsMay 03, 2024
High Blood Pressure in Youth: A Precursor to Severe Heart ConditionsMay 03, 2024
Microplastics in Human Brains: Understanding the Emerging Health ConcernMay 03, 2024
Federal Bank Wraps Up FY 24 With 24% Rise in Profit, highest NII, Maintains Robust Asset QualityMay 02, 2024
Two Aveksha Day Care Centers for Construction Workers’ Children opened on the occasion of Labour Day May 02, 2024
AbbVie India and Sightsavers India Collaborate to Raise Awareness on GlaucomaMay 02, 2024
Whither social justice and decent work for women?May 02, 2024
Hyderabad's senior anesthesiologist at the L V Prasad Eye Institute, Dr Raja Narsing Rao elected as President of the World Congress of Ophthalmic AnaesthesiaMay 02, 2024
Navigating Legal Waters: Covishield's Side Effects Prompt Legal Battle from Parents May 02, 2024
Mumps Resurgence in India: Understanding the Recent Outbreak and Prevention StrategiesMay 02, 2024